TECHNICAL SPECIFICATION
TypeCX 40System Voltage12/24 V auto recognitionMax. Charge /Load Current40 AFloat Charge13.7/27.4 V (25 °C)Main Charge14.4/28.8 V (25 °C), 30 min. (daily)Boost Charge
14.4/28.8 V (25 °C), 2 h
Activation: battery voltage <12.3/24.6 V
Equalization
14.8/29.6 V (25 °C), 2 h
Activation: battery voltage <12.1/24.2 V
Deep discharge protection:
State of charge dependent
Voltage dependent
Adaptive Reconnect level
A: 11.4 – 11.9 V /22.8 – 23.8 V
B: 11.0 – 11.75 V / 22.0 – 23.5 V A: 11.0/22 V
B: 11.5/23 V
11.0 – 12.2 V / 22.0 – 24.4 V
12.8/25.6 VOvervoltage Protection15.5/31.0 VUndervoltage Protection10.5/21.0 VMax. panel voltage
(Overvoltage protection by varistor)30 V in 12 V system