    Manufacturer: Ceasefire Industries Ltd

    Wireless Pro Panel

    Call for pricing
    Introduces: Pro Wireless, a wireless fire alarm system designed to take detection to a whole new level. The system is governed by the Pro Control Panel, a panel fully capable of automatically collecting data from the various sensors. The very instant a fire is detected, the detectors wirelessly talk to the Pro Panel, which in turn triggers a response, raising the alarm and displaying the exact location of the threat on the LCD screen.

    TECHNICAL SPECIFICATION

    Zones Number:  28 wireless, 2 hardwired (zones 29 & 30).
    Hardwired Zone Requirements:2.2 kΩ E.O.L. resistance (max. resistance of wires 220 Ω).
     Zone Types:  Interior follower, interior, perimeter, perimeter follower, delay 1, delay 2, 24h silent, 24h audible, fire, nonalarm, emergency, gas, flood, temperature and interior /perimeter.
    Display:  Single line, Backlit 16-character LCD.
     Alarm Types:  Silent alarm, siren alarm or sounder (internal) alarm, in accordance with zone attributes.
    Siren Signals:  Continuous (intrusion / 24 hours / panic); triple pulse - pause - triple pulse... (fire).
    Siren (bell) Timeout:Programmable
    Internal Sounder Output:  At least 85 dBA at 10 ft (3 m)
    Supervision:  Programmable time frame for inactivity alert
     Data Retrieval:  Status, alarm memory, trouble, event log.
     Compliance with U.S. Standards:  Meets FCC Part 15 and Part 68 requirements. Ul1637, UL1635, UL1023, UL985, ULC-S545-02, ULC  C1023.
    Receiver Type:  Super-heterodyne, fixed frequency
     Receiver Range:  600 ft (180 m) in open space
     Antenna Type:  Spatial diversity
    Coding:  PowerCode and/or CodeSecure™
    Power Supply:  Internal switching power supply 100VAC to 240VAC, 50/60 Hz, 0.5A / 12.5 VDC, 1.6A.
     Maximum Output Ripple:  0.05
     Current Drain:  Approx. 40 mA standby, 1400 mA at full load and in alarm.
     Site External Siren Current (EXT):  450* mA max @ 10.5 VDC minimum when powered by AC & DC (battery).
    Site Internal Siren Current (INT):  450* mA max. @ 10.5 VDC minimum when powered by AC & DC (battery)
     PGM Output Current:  100* mA max.
     Wired Detectors (zones 29 & 30) 
    Total (Sum) Current:  36* mA max.
    High Current / Short Circuit Protection:   All outputs are protected (automatic reset fuse). 
     Total Pro Panel output current: 550 mA.
    Maximum battery recharge time:  72 hours
    Battery Test:  Once every 10 seconds.
     Built-in Modem: 300 baud, Bell 103 protocol
    Data Transfer to Local Computer:  Via RS232 serial port 
    Report Destinations: 2 central stations, 4 private telephones
     Reporting Format Options:  SIA, Pulse 4/2 1900/1400 Hz, Pulse 4/2 1800/2300 Hz, Contact ID, Scancom.
     Pulse Rate:  10, 20, 33 and 40 pps – programmable
     Message to Private Phones:  Tone or voice
     Message to Pager:   PINNo Zone No.Pin No. * Alarm Type * Zone No.
    Operating Temp. Range:  14°F to 120°F (-10°C to 49°C)
    Storage Temp. Range:  -4°F to 140°F (-20°C to 60°C)
     Humidity:  85% relative humidity, @ 30°C (86°F)
     Dimensions:  285 x 215 x 55 mm
    Weight:  1600 g ms

    Write your own review
    • Only registered users can write reviews
    *
    *
    • Bad
    • Excellent
    *
    *
    *
    *

    TECHNICAL SPECIFICATION

    Zones Number:  28 wireless, 2 hardwired (zones 29 & 30).
    Hardwired Zone Requirements:2.2 kΩ E.O.L. resistance (max. resistance of wires 220 Ω).
     Zone Types:  Interior follower, interior, perimeter, perimeter follower, delay 1, delay 2, 24h silent, 24h audible, fire, nonalarm, emergency, gas, flood, temperature and interior /perimeter.
    Display:  Single line, Backlit 16-character LCD.
     Alarm Types:  Silent alarm, siren alarm or sounder (internal) alarm, in accordance with zone attributes.
    Siren Signals:  Continuous (intrusion / 24 hours / panic); triple pulse - pause - triple pulse... (fire).
    Siren (bell) Timeout:Programmable
    Internal Sounder Output:  At least 85 dBA at 10 ft (3 m)
    Supervision:  Programmable time frame for inactivity alert
     Data Retrieval:  Status, alarm memory, trouble, event log.
     Compliance with U.S. Standards:  Meets FCC Part 15 and Part 68 requirements. Ul1637, UL1635, UL1023, UL985, ULC-S545-02, ULC  C1023.
    Receiver Type:  Super-heterodyne, fixed frequency
     Receiver Range:  600 ft (180 m) in open space
     Antenna Type:  Spatial diversity
    Coding:  PowerCode and/or CodeSecure™
    Power Supply:  Internal switching power supply 100VAC to 240VAC, 50/60 Hz, 0.5A / 12.5 VDC, 1.6A.
     Maximum Output Ripple:  0.05
     Current Drain:  Approx. 40 mA standby, 1400 mA at full load and in alarm.
     Site External Siren Current (EXT):  450* mA max @ 10.5 VDC minimum when powered by AC & DC (battery).
    Site Internal Siren Current (INT):  450* mA max. @ 10.5 VDC minimum when powered by AC & DC (battery)
     PGM Output Current:  100* mA max.
     Wired Detectors (zones 29 & 30) 
    Total (Sum) Current:  36* mA max.
    High Current / Short Circuit Protection:   All outputs are protected (automatic reset fuse). 
     Total Pro Panel output current: 550 mA.
    Maximum battery recharge time:  72 hours
    Battery Test:  Once every 10 seconds.
     Built-in Modem: 300 baud, Bell 103 protocol
    Data Transfer to Local Computer:  Via RS232 serial port 
    Report Destinations: 2 central stations, 4 private telephones
     Reporting Format Options:  SIA, Pulse 4/2 1900/1400 Hz, Pulse 4/2 1800/2300 Hz, Contact ID, Scancom.
     Pulse Rate:  10, 20, 33 and 40 pps – programmable
     Message to Private Phones:  Tone or voice
     Message to Pager:   PINNo Zone No.Pin No. * Alarm Type * Zone No.
    Operating Temp. Range:  14°F to 120°F (-10°C to 49°C)
    Storage Temp. Range:  -4°F to 140°F (-20°C to 60°C)
     Humidity:  85% relative humidity, @ 30°C (86°F)
     Dimensions:  285 x 215 x 55 mm
    Weight:  1600 g ms